Axial piston unit of bent axis design with fixed displacement, for use as either pump or motor in hydrostatic drive,in open or closed circuit.
Operated as a pump,the flow is proportional to the drive speed and displacement.
Operated as a motor ,the output speed is proportional to the volume and inversely proportional to displacement.The output torque increase with the pressure drop between the high and low pressure sides.
Size | HA2FM | 5 | 10 | 12 | 16 | 23 | 28 | 32 | 45 | 56 | 63 | 80 | ||
Displacement | Vg | cm³ | 4,93 | 10,3 | 12 | 16 | 22,9 | 28,1 | 32 | 45,6 | 56,1 | 63 | 80,4 | |
Speed 1) | nmax | rpm | 10000 | 8000 | 8000 | 8000 | 6300 | 6300 | 6300 | 5600 | 5000 | 5000 | 4500 | |
Flow | at nmax | qVmax | l/min | 49 | 82 | 96 | 128 | 144 | 176 | 201 | 255 | 280 | 315 | 360 |
Torque | Δp = 315 bar | Tmax | Nm | 24,7 | - | - | - | - | - | - | - | - | - | - |
Δp = 400 bar | Tmax | Nm | - | 65 | 76 | 100 | 144 | 178 | 204 | 290 | 356 | 400 | 508 | |
Weight (approx.) | m | kg | 2,5 | 5,4 | 5,4 | 5,4 | 9,5 | 9,5 | 9,5 | 13,5 | 18 | 18 | 23 | |
Size | HA2FM | 90 | 107 | 125 | 160 | 180 | 200 | 250 | 355 | 500 | 710 | 1000 | ||
Displacement | Vg | cm³ | 90 | 106,7 | 125 | 160,4 | 180 | 200 | 250 | 355 | 500 | 710 | 1000 | |
Speed 1) | nmax | rpm | 4500 | 4000 | 4000 | 3600 | 3600 | 2750 | 2700 | 2240 | 2000 | 1600 | 1600 | |
Flow | at nmax | qVmax | l/min | 405 | 427 | 500 | 577 | 648 | 550 | 675 | 795 | 1000 | 1136 | 1600 |
Torque | Δp = 350 bar | Tmax | Nm | - | - | - | - | - | - | 1393 | 1978 | 2785 | 3955 | 5570 |
Δp = 400 bar | Tmax | Nm | 572 | 680 | 796 | 1016 | 1144 | 1272 | - | - | - | - | - | |
Weight (approx.) | m | kg | 23 | 32 | 32 | 45 | 45 | 66 | 73 | 110 | 155 | 325 | 336 |